Friday, March 23, 2012

iolite Portable Vaporizer (Black)

!±8±iolite Portable Vaporizer (Black)

Brand : Iolite
Rate :
Price : $99.95
Post Date : Mar 23, 2012 04:24:58
Usually ships in 24 hours



For direct inhalation of vapour the iolite portable vaporiser, creates the heat you need to vaporise, anytime, anywhere, within 45 seconds. More than just a sleek lightweight design, the iolite is a powerful portable vaporizer that appeals to everyone, from the light to intense user - making vaporising a whole lot easier on the go. Combining a smart design with innovative technology the iolite is the next generation in vaporising. Oglesby & Butler technology expanded into the vaporiser market in 2009 with the portable revolution of the iolite® portable vaporizer. Our iolite vaporizer features our unique bi-metal thermostat, which regulates the temperature to a constant 190ºC so as not to burn. With the iolite® vaporizer patented in over 150 countries we are aiming to provide the world the best in butane powered portable vaporisers for smokeless freedom. With a state of the art tool room including Star and Deco CNC machines, a plating plant, catalyst lab and moulding shop iolite® products are designed and manufactured by a team of dedicated and valued employees at our manufacturing plant in Carlow, Ireland. All our products are proudly stamped "Déanta in Éirinn" - Made in Ireland.

Discounted Lcd 1080p Tv Frye Shirley Boots Best Quality Coupon At&t Cell

Tuesday, March 6, 2012

Q Industries MV50 SuperFlow High-Volume Air Compressor

!±8± Q Industries MV50 SuperFlow High-Volume Air Compressor

Brand : Q Industries | Rate : | Price : $79.95
Post Date : Mar 06, 2012 05:34:05 | Usually ships in 24 hours


  • Inflate a tire in less than 2 1/2 minutes
  • 120 PSI air compressor
  • 16-foot coiled hose
  • Storage bag included
  • Ideal for off-road vehicles

More Specification..!!

Q Industries MV50 SuperFlow High-Volume Air Compressor

Summer Infant Walk Thru Gate Sale Bose Soundlink Save You Money!

Tuesday, January 10, 2012

What Your Spa Or Hot Tub is Trying to Tell You

!±8± What Your Spa Or Hot Tub is Trying to Tell You

You walk out to use your spa or hot tub and immediately you know something is wrong. Either the water is cold, which makes for a less than enjoyable soak or nothing is working at all. The spa appears dead.

If you have a digital system in your spa or hot tub with a digital upper control, you first look at the upper control display to see if it will tell you what is going on. Looking at your upper control, you see abbreviations like SN1 or FLO or even "----". What do these symbols and abbreviations mean?

The symbols and abbreviations displayed on your spas upper control are called error codes. They tell you that the spa has detected a situation for which it then tries to identify. Different equipment manufacturers use different codes to identify certain conditions found by the spa self diagnostic system.

We will look at the two spa systems I receive most questions about. Balboa controls and Sundance Spas controls.

Balboa, one of the most common spa controls manufacturers, uses the following codes.

pd = Power supply, unit running on battery backup

OH = Sensors reading 112-118 Degrees

Flo = Improper flow or pressure switch malfunction

Cool = Water temp 20 degrees below set point

ICE = Potential freeze condition has been detected

Sn1 = Hi-limit sensor malfunction

Sn3 = Temp sensor malfunction

LOC = Interlock failure - possible pump or ozone spike

(----) = Unknown water temperature. (Displays when Spa is first powered up after refill).

Sundance Spa, one of the largest spa manufacturers, uses the following error codes.

ILOC = Interlock failure - possible pump or ozone spike

FLO = Pressure switch malfunction or Flow switch malfunction (system specific).

Hold = Flow Switch (heater is deactivated. Pump may also be deactivated).

Hold = Panel buttons pressed to many times to quickly.

HOT = PCB temperature above acceptable limit - air blower on.

ICE = Potential freeze condition.

PnL = Communication between the panel and circuit board is faulty.

(----) = "WATCHDOG" (spa is deactivated) A problem has been detected. (system can not identify)

Sn1 = OPEN SENSOR (heater is deactivated) or SHORTED SENSOR (spa is deactivated).

Sn3 = OPEN SENSOR OR SHORTED SENSOR ( heater disabled).

(This is not a complete list and your spa error codes may vary depending on year and model.)

Notice the similarities and differences in the codes. Both use FLO,SN1,SN3 and ICE and so forth, Differences include, (----). Meaning totally different things between the two systems. You must use the error codes for your control system to accurately diagnose the problem with your spa.

Lets take a quick look at the FLO error code. Both manufacturers state FLO is caused when a pressure switch malfunctions or a flow switch malfunctions. This can be the case in many situations, however, it is my experience that the number one cause of a spa displaying the error code "FLO" is due to a dirty or worn out filter.

(Some manufacturers attempt to narrow down the FLO error with different displays of the code, i.e., a solid FLO or a flashing FLO (FLO error blinks off and on).

Blinking FLO = Heater has been deactivated, pump is on and Flow / Pressure switch are open. (This means the system detects the spa has called for heat, the PC board has applied power to the pump, but it has not detected water flow. It deactivates the heater to avoid damage to the heater).

Solid FLO = Pump is off, flow or pressure switch is closed. (Meaning, the system should not be detecting water flow because the PC Board has not applied power to the pump, but the flow pressure switch is saying there is water flow. The flow or pressure switch is stuck in the closed position or shorted.)

A dirty or worn out filter can cause several error codes to be displayed. "OH" (over heat) because water is not moving quickly enough through the heater vessel and the high limit detects too hot of water temperature. "FLO" because the filter will not allow enough water through the heater vessel to activate the flow or pressure switch. Filters should be replaced approximately annually or bi-annually if you use two different filters. Filters should be rinsed thoroughly every month, and cleaned properly every 3 months or so.

For more information on error codes for your spa, visit Spa Parts Supply or contact your spa manufacturer for a list of codes that pertain to your spa. When in doubt, call a spa service technician for troubleshooting help and repair.